Background: To assess the constants and formula for aphakia correction with iris-claw IOLs to achieve the best refractive status in cases of late in-the-bag IOL complex dislocation. Methods: A literature search was performed. The following data were obtained: Iris-claw IOL model, Iridal or retroiridal enclavation, A-constant, ultrasound or optical biometry, formula employed and refractive outcomes. Acceptable emmetropia was considered if the resulting spherical equivalent (SE) was within ±1.00 D. Results: The majority of the studies used SRK/T formula (66.6%). The 88.9% of the reports obtained a SE within ±1.
00 D. Using A-115 for ultrasound biometry and A-115.7 for optical biometry and SRK/T formula, the emmetropia (±1.00 D) of SE, was able to get near 100% of reported cases over the pupil implantation. However, the emmetropia decreased to 80% when the enclavation is retropupilar using the same formula. The A-constant can vary from 116.7 to 117.5 for retropupilar enclavation. Conclusions: Using A-115 for ultrasound biometry and A-115.7 for optical biometry and SRK/T formula, ±1.00 D of SE, is able to get near 100% of cases. Nevertheless, ±1.00 D of SE decreased to 80% of the cases when the enclavation is retropupilar.
Is part of
BMC Ophthalmology, 2017, vol. 17, p. 122European research projects
Collections
The following license files are associated with this item: