Show simple item record

dc.contributor.authorMedrano Martorell, Marc
dc.contributor.authorMartí, Josep Maria
dc.contributor.authorRincón, Lídia
dc.contributor.authorMor, Gerard
dc.contributor.authorCipriano, Jordi
dc.contributor.authorFarid, Mohammed M.
dc.date.accessioned2018-02-14T12:09:11Z
dc.date.available2018-02-14T12:09:11Z
dc.date.issued2018-02-11
dc.identifier.issn2251-6832
dc.identifier.urihttp://hdl.handle.net/10459.1/62659
dc.description.abstractPublic universities face the challenge of retrofitting the actual campus buildings into nearly zero-energy buildings (NZEB). In this study, a novel methodology for evaluating historical energy use and renewable energy production for all the buildings of a university, including hourly, daily and monthly data assessments is presented. This analysis is useful as a baseline for comparisons with future energy retrofits and enables determining the current gap between actual energy indicators at building and campus levels and the established limits for NZEB non-residential buildings in the European Union. The methodology is applied to a case study at the University of Lleida, a typical average-size university in Spain. Results show a wide variation in energy use among campus buildings, ranging between 50 and 470 kWh/m2 year. Constant or slightly increasing energy use and decreasing trends in renewable energy generation are observed. The daily electricity profiles have shown similar patterns among buildings and substantial potential energy savings during unoccupied periods. In the NZEB analysis, the average non-renewable primary energy use is about 4 times higher than the maximum estimated Spanish threshold range of 45-55 kWh/m2 year. Deep energy renovation strategies are, thus, needed for universities to meet EU NZEB targets.
dc.description.sponsorshipThe research leading to these results has received funding from the European Union’s Seventh Framework Programme (FP7/2007-2013) under grant agreement no. PIRSES-GA-2013-610692 (INNOSTORAGE).
dc.format.mimetypeapplication/pdf
dc.language.isoeng
dc.publisherSpringer
dc.relation.isformatofReproducció del document publicat a https://doi.org/10.1007/s40095-018-0264-x
dc.relation.ispartofInternational Journal of Energy and Environmental Engineering (IJEEE), 2018, p. 1-21
dc.rightscc-by (c) Medrano, et al, 2018
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.titleAssessing the nearly zero-energy building gap in university campuses with a feature extraction methodology applied to a case study in Spain
dc.typeinfo:eu-repo/semantics/article
dc.date.updated2018-02-14T12:09:12Z
dc.identifier.idgrec026693
dc.type.versionpublishedVersion
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.identifier.doihttps://doi.org/10.1007/s40095-018-0264-x
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/FP7/610692


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

cc-by (c) Medrano, et al, 2018
Except where otherwise noted, this item's license is described as cc-by (c) Medrano, et al, 2018