Universitat de Lleida
    • English
    • català
    • español
  • català 
    • English
    • català
    • español
  • Inicia la sessió
Repositori Obert UdL
Visualitza l'element 
  •   Inici
  • Recerca
  • Química
  • Articles publicats (Química)
  • Visualitza l'element
  •   Inici
  • Recerca
  • Química
  • Articles publicats (Química)
  • Visualitza l'element
JavaScript is disabled for your browser. Some features of this site may not work without it.

Steady-state currents at inlaid and recessed microdisc electrodes for first-order EC′reactions

Thumbnail
Visualitza/Obre
Postprint (1.239Mb)
Data de publicació
1999
Autor/a
Galceran i Nogués, Josep
Taylor, S. L.
Bartlett, P. N.
Citació recomanada
Galceran i Nogués, Josep; Taylor, S. L.; Bartlett, P. N.; . (1999) . Steady-state currents at inlaid and recessed microdisc electrodes for first-order EC′reactions. Journal of Electroanalytical Chemistry, 1999, vol. 476, num. 2, p. 132-147. https://doi.org/10.1016/S0022-0728(99)00378-2.
Impacte


Logo de Web of Science    citacions a Web of Science

Logo d'Scopus    citacions a Scopus

Logo de Google Acadèmic  Google Acadèmic
Compartir
Exportar a Mendeley
Metadades
Mostra el registre d'unitat complet
Resum
The analytical solutions, approximate expressions and a Finite Element simulation of the steady-state currents arising from the diffusion of a regenerating electroactive species towards a disc electrode, either inlaid in an insulator or recessed, are discussed. The results are valid for any reversible charge transfer, regardless of the applied potential (i.e. including limiting currents) and for an equal or unequal diffusion coefficient of the species. For the inlaid disc, derivation of the exact analytical solution, via a reformulation of the diffusion-reaction problem as a dual integral equation that can then be solved using a series of Bessel functions, allows us to assess and review the accuracy of existing approximate expressions. We present three new formulae for the steady-state current under these conditions, among which we highlight one with an accuracy better than 0.27% over the entire range of rate constants and we show that the accuracy of a recently presented two point Padé approximation (L. Rajendran and M.V. Sangaranarayanan, J. Phys. Chem. B 103 (1999) 1518) is better than 0.01%. The analytical solution also allows us to show that the accuracy of the simulation of the same problem using the Finite Element Method is better than 0.4%. For the recessed disc the exact analytical solution is derived, as an extension of the solution of the inlaid disc, by matching the series representing the concentration of the electroactive species and its derivative. Two approximate expressions are suggested, one of which yields at least 2% accuracy. Concentration profiles for the electroactive species provide physical insight into the processes involved.
URI
http://hdl.handle.net/10459.1/48895
DOI
https://doi.org/10.1016/S0022-0728(99)00378-2
És part de
Journal of Electroanalytical Chemistry, 1999, vol. 476, num. 2, p. 132-147
Projectes de recerca europeus
Col·leccions
  • Articles publicats (Química) [241]

Publicacions relacionades

Mostrant elements relacionats per títol, autor i matèria.

  • Application of Danckwerts' expression to first-order EC′reactions. Transient currents at inlaid and recessed microdisc electrodes 

    Galceran i Nogués, Josep; Taylor, S. L.; Bartlett, P. N. (Elsevier, 1999)
    A general relationship, arising from Danckwerts' expression (P.V. Danckwerts, Trans. Faraday Soc. 47 (1951) 1014), allows the computation of the transient limiting current in a system with a homogeneous first-order reaction ...
  • Modelling the steady-state current at the inlaid disc microelectrode for homogeneous mediated enzyme catalysed reactions 

    Galceran i Nogués, Josep; Taylor, S. L.; Bartlett, P. N. (Elsevier, 2001)
    The steady-state currents at an inlaid microdisc electrode have been modelled for a redox mediated enzyme catalysed reaction (such as the glucose/glucose oxidase/ferrocene system) in which all the components are present ...
  • Computing steady-state metal flux at microorganism and bioanalogical sensor interfaces in multiligand systems. A reaction layer approximation and its comparison with the rigorous solution 

    Buffle, Jacques; Startchev, Konstantin; Galceran i Nogués, Josep (The Royal Society of Chemistry, 2007)
    In complicated environmental or biological systems, the fluxes of chemical species at a consuming interface, like an organism or an analytical sensor, involve many coupled chemical and diffusion processes. Computation of ...

Contacteu amb nosaltres | Envia comentaris | Avís legal
© 2021 BiD. Universitat de Lleida
Metadades subjectes a 
 

 

Explora

Tot el repositoriComunitats i col·leccionsPer data d'edicióAutorsTítolsMatèriesAquesta col·leccióPer data d'edicióAutorsTítolsMatèries

Estadístiques

Veure estadístiques d'ús

D'interès

Política institucional d'accés obertDiposita les teves publicacionsDiposita dades de recercaSuport a la recerca

Contacteu amb nosaltres | Envia comentaris | Avís legal
© 2021 BiD. Universitat de Lleida
Metadades subjectes a