Show simple item record

dc.contributor.authorGracia Cuesta, Alvaro de
dc.contributor.authorNavarro Farré, Lidia
dc.contributor.authorCastell, Albert
dc.contributor.authorRuiz-Pardo, Álvaro
dc.contributor.authorÁlvarez, Servando
dc.contributor.authorCabeza, Luisa F.
dc.date.accessioned2015-02-09T08:15:23Z
dc.date.issued2013
dc.identifier.issn0378-7788
dc.identifier.urihttp://hdl.handle.net/10459.1/47896
dc.description.abstractA new type of ventilated facade (VF) with macro-encapsulated phase change material (PCM) in its air cavity is presented in this paper. The thermal performance of this special building envelope is experimentally tested to analyze its potential in reducing the cooling demand during the summer season in the Continental Mediterranean climate. Two identical house-like cubicles located in Puigverd de Lleida (Spain) were monitored during summer 2012, and in one of them, a ventilated facade with PCM was located in the south wall. Six automatized gates were installed at the different openings of the channel in order to control the operational mode of the facade. This versatility allows the system to be used as a cold storage unit, as an overheating protection system or as a night free cooling application. The experimental results point out the night free cooling effect as the most promising operational sequence to reduce the cooling load of the cubicle. On the other hand, the thermal resistance of the outer skin of the facade must be increased; otherwise the cold storage system cannot be used efficiently.ca_ES
dc.description.sponsorshipThis work was supported by the “Corporación Tecnológica de Andalucía” by means of the project “MECLIDE-Soluciones estructurales con materiales especiales para la climatización diferida de edificios” with the collaboration of DETEA. The work partially funded by the Spanish government (ENE2011-28269-C03-02 and ULLE10-4E-1305) and the European Union (COST Action COST TU0802). The authors would like to thank the Catalan Government for the quality accreditation given to their research group (2009 SGR 534).
dc.language.isoengca_ES
dc.publisherElsevierca_ES
dc.relationMICINN/PN2008-2011/ENE2011-28269-C03-02
dc.relation.isformatofReproducció del document publicat a https://doi.org/10.1016/j.enbuild.2013.06.032ca_ES
dc.relation.ispartofEnergy and Buildings, 2013, vol. 65, p. 508-515ca_ES
dc.rights(c) Elsevier, 2013ca_ES
dc.subjectVentilated facadeca_ES
dc.subjectPhase change materialsca_ES
dc.subjectBuildingsca_ES
dc.titleThermal analysis of a ventilated facade with PCM for cooling applicationsca_ES
dc.typearticleca_ES
dc.identifier.idgrec019762
dc.type.versionpublishedVersionca_ES
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccessca_ES
dc.identifier.doihttps://doi.org/10.1016/j.enbuild.2013.06.032
dc.date.embargoEndDate10000-01-01